Detection system helps radiologists quickly, more accurately spot major findings on chest X-rays

Radiologists more accurately spotted major abnormalities on chest X-rays with the help of a deep learning-based detection system, according to results of a new randomized study.

A number of prior investigations have revealed the power of artificial intelligence algorithms as a second reader, yet all past research has asked rads to interpret exams sequentially, experts explained Tuesday in Radiology. Looking at images with CAD assistance and then without quickly introduces reader order bias, they noted.

Utilizing a randomized, crossover design, the investigators showed imaging professionals—including an experienced thoracic radiologist— were quicker and more accurate at detecting abnormalities when using CAD.

“In the rigorous setting of our study, which minimized bias, the diagnostic performance of the radiologists was substantially improved with the assistance of the DLD system,” Jinkyeong Sung, and colleagues with Asan Medical Center’s Department of Radiology in Seoul, South Korea, wrote on March 23.

To arrive at their conclusions, the authors retrospectively collected 114 abnormal and 114 normal chest radiographs between January 2016 and December 2017. Six readers interpreted each image using the deep learning system and then again without it, abiding by the crossover design and washout period.

With the detection software, radiologists improved in a number of areas. For instance, localization rose from 0.90 to 0.95 and area under the receiver operating curve scores jumped from 0.93 to 0.98. At the same time, per-lesion sensitivity and specificity both increased along with per-image sensitivity.

Furthermore, the deep learning-based system dropped read times from 10-65 seconds down to 6-27 seconds, the authors reported.

Sung and co-authors encouraged future studies to go beyond the single-center design utilized for their own research in order to make sure this system is ready for clinical use.

“Further studies in other institutions and countries are needed to ensure generalizability,” the authors concluded. “In addition, future studies in a real-world setting will help determine the usefulness of the DLD system.”

""

Matt joined Chicago’s TriMed team in 2018 covering all areas of health imaging after two years reporting on the hospital field. He holds a bachelor’s in English from UIC, and enjoys a good cup of coffee and an interesting documentary.

Around the web

Positron, a New York-based nuclear imaging company, will now provide Upbeat Cardiology Solutions with advanced PET/CT systems and services. 

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.