High-spatial resolution CT could benefit those at high risk for coronary artery disease

Improved evaluability and accuracy was seen with high spatial resolution in comparison with standard spatial resolution coronary CT angiography of calcified coronary artery lesions, according to a study published online Feb. 8 by Radiology.

Lead author Gianluca Pontone, MD, of the Centro Cardiologico Monzino in Milan, Italy, and colleagues compared the image quality, evaluability, diagnostic accuracy, and radiation exposure of high spatial coronary CT angiography with those of CT angiography with a standard spatial resolution in patients at high risk for coronary artery disease (CAD) by using invasive coronary angiography as the reference method.

The study included 197 consecutive patients who were at high risk for CAD and scheduled for an invasive coronary angiography.  These participants were randomized to undergo standard or high spatial resolution coronary CT angiography and were examined with invasive coronary angiography within a week after the imaging.

Results revealed that high spatial resolution coronary CT angiography had a higher image quality score than the standard, with a score of 3.7 versus 3.4. The evaluability of the high spatial resolution was also higher at 97 percent versus 92 percent. High spatial resolution coronary CT angiography also had a higher specificity, positive predictive value, and accuracy. Importantly, it demonstrated a better agreement with invasive coronary angiography for calcified plaques than standard spatial resolution coronary CT angiography.

“Patients at high risk of coronary artery disease, who are more likely to have multiple calcified plaques and a risk of overestimation of stenosis secondary to blooming from calcification, may benefit from this technology,” concluded Pontone and colleagues.

The study’s authors suggest the need to conduct further research in order to compare the technology with other technological approaches that reduce artifacts related to calcified plaques. 

Around the web

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.

The newly cleared offering, AutoChamber, was designed with opportunistic screening in mind. It can evaluate many different kinds of CT images, including those originally gathered to screen patients for lung cancer. 

Trimed Popup
Trimed Popup