New research highlights key factors associated with the resolution of reactive lymphadenopathy visualized on breast imaging after patients receive an mRNA COVID vaccine. 

“The variable clinical course of subclinical lymphadenopathy detected on breast imaging after COVID-19 vaccination creates management challenges and has led to evolving practice recommendations,” corresponding author Michele B. Drotman, MD, from the Department of Radiology at Weill Cornell Medicine, and co-authors explained. 

Vaccine-related lymphadenopathy is a well-documented side effect of mRNA COVID vaccines but, until recently, little was known about the specifics pertaining to its clinical course and resolution. A new study published in the American Journal of Roentgenology this week confirmed prior findings that indicated the reactive inflammation is benign in nature and can take weeks to resolve, and also took the research a step further by characterizing features that are associated with the amount of time it takes for the side effect to fully subside. 

This involved retrospectively assessing 111 women who experienced axillary lymphadenopathy ipsilateral to either a Pfizer or Moderna COVID vaccine. After the findings were initially detected via ultrasound (within 8 weeks of inoculation), the women underwent follow-up ultrasound imaging in 4 to 12 week intervals until the lymphadenopathy resolved. 

The researchers found the reactive inflammation subsided 127±43 days after the first vaccine dose and 97±44 days after the initial ultrasound. Significant associations between shorter resolution times and Pfizer vaccinations were observed (compared to Moderna vaccination) in addition to longer resolution times for the women who received their second vaccine dose after having already developed lymphadenopathy. 

Imaging features were also examined as predictive factors, with cortical thickness of the nodes being of particular interest. Greater cortical thickness observed on initial imaging was found to be an independent predictor of lengthier resolution times. 

Patient factors, such as age, prior history of breast cancer, and axillary symptoms did not appear to be associated with time to resolution. 

Axillary lymphadenopathy detected by breast ultrasound after COVID-19 mRNA vaccination lasts longer than reported in initial vaccine clinical trials,” the author wrote. “The prolonged time for resolution supports not delaying screening mammography due to recent COVID-19 vaccination as well as the recent professional society recommendation of a follow-up interval of at least 12 weeks for suspected vaccine-related lymphadenopathy.” 

More on vaccine-related lymphadenopathy: 

Experts suggest new follow-up imaging protocols for vaccine-related lymphadenopathy

These ultrasound features distinguish between COVID vaccine-related and malignant adenopathy

FDG PET/CT radiomics distinguishes between vaccine-related or metastatic breast cancer lymphadenopathy

Mammograms should not be delayed after COVID vaccine, research shows

References: 

Time for Resolution of COVID-19 Vaccine-Related Lymphadenopathy and Associated Factors,” Elizabeth G. Lane, Carolyn S. Eisen, Michele B. Drotman, Katerina Dodelzon, Eralda Mema, Charlene Thomas, and Martin R. Prince, American Journal of Roentgenology. 

Hannah murhphy headshot

In addition to her background in journalism, Hannah also has patient-facing experience in clinical settings, having spent more than 12 years working as a registered rad tech. She joined Innovate Healthcare in 2021 and has since put her unique expertise to use in her editorial role with Health Imaging.

Around the web

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.

The newly cleared offering, AutoChamber, was designed with opportunistic screening in mind. It can evaluate many different kinds of CT images, including those originally gathered to screen patients for lung cancer. 

Trimed Popup
Trimed Popup