Polyps characterized as both sessile and serrated lead to as many as 30 percent of all colorectal cancers, and they’re very good at avoiding detection by CT colonography—while quite readily giving themselves up to colonoscopy—according to a study published earlier this spring in the American Journal of Gastroenterology.

Joep Ijspeert, MD, of the University of Amsterdam in the Netherlands and colleagues compared the performance of the two modalities as applied to population screening for high-risk sessile serrated polyps (SSPs) in average-risk individuals.

Patients diagnosed by CT colonography with a lesion at least 10 millimeters in size were referred for colonoscopy.

Those with lesions of six to nine millimeters were offered surveillance CT colonography followed by colonoscopy when a lesion of six millimeters or more was detected.

The researchers aggregated data from both groups to mimic American College of Radiology CT colongraphy referral recommendations.

Of 8,844 patients invited to participate, 1,276 colonoscopy and 982 CT colonography invitees agreed.

In the colonoscopy arm, 4.3 percent of individuals were diagnosed with one or more high-risk SSP lesions, compared with 0.8 percent in the CT colonography arm, the authors report.

In total, 3.1 percent of patients in the colonoscopy arm were diagnosed with high-risk SSPs as the most advanced lesion, compared with 0.4 percent in the CTC arm.  

And the current CT colonography strategy yielded markedly lower detection for especially flat high-risk SSPs (17 vs. 0), high-risk SSP located in the proximal colon (32 vs. 1) and SSPs with dysplasia (30 vs. 1).

In their discussion, Ijspeert and team conclude that these shortcomings of CT colonography as compared with colonoscopy “might have implications for the value of CT colonoscopy as a primary colorectal cancer screening tool in opportunistic screening.”

They add that results from other large screening cohorts are needed “to elaborate our findings and to determine the performance of CT colonography in the detection of advanced neoplasia, including high-risk SSPs, compared with the performance of colonoscopy, both in an opportunistic as well as a population-based screening setting taking into account other variables such as participation.”

Dave Pearson

Dave P. has worked in journalism, marketing and public relations for more than 30 years, frequently concentrating on hospitals, healthcare technology and Catholic communications. He has also specialized in fundraising communications, ghostwriting for CEOs of local, national and global charities, nonprofits and foundations.

Around the web

Positron, a New York-based nuclear imaging company, will now provide Upbeat Cardiology Solutions with advanced PET/CT systems and services. 

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.