Minimally invasive ultrasound-guided biopsy a fine diagnostic for nonpalpable breast lesions

Breast lesions that physicians can’t feel by palpation are little match for fine-needle aspiration guided by ultrasound, although the procedure’s performance varies somewhat with the age of the patient and the BI-RADS category of the lesion.

That’s according to a study conducted at the Curie Institute in Paris and published online May 13 in the American Journal of Clinical Pathology.

Josep Farras Roca, MD, and colleagues assessed 2,601 nonpalpable breast lesions that were biopsied ultrasound-guided fine-needle aspiration (USFNA), a relatively gentle biopsy procedure, as performed by a radiologist-pathologist team.

The researchers based gold-standard diagnosis on surgery, core-needle biopsy or one-year imaging follow-up.

Analyzing the method’s diagnostic performance in different clinical and imaging subgroups, they found:

  • USFNA’s sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were, respectively, 92.6 percent, 96.8 percent, 94.8 percent and 95.4 percent.
  • The best PPV was achieved in BI-RADS categories 4C and 5. The best NPV was achieved in BI-RADS categories 2, 3 and 4A and in patients younger than 50.
  • The BI-RADS categories, associated palpable cancer, mitotic count (indicating whether and/or how rapidly the tumor cells are dividing) and age (under 50 vs. 50 or older) were statistically independent factors between USFNA’s false-negative and true-positive results.

Ultrasound-guided fine-needle aspiration “is a robust diagnostic procedure in nonpalpable breast lesions,” the authors conclude. “Age and the BI-RADS category of the lesion are important factors determining its performance.”

Dave Pearson

Dave P. has worked in journalism, marketing and public relations for more than 30 years, frequently concentrating on hospitals, healthcare technology and Catholic communications. He has also specialized in fundraising communications, ghostwriting for CEOs of local, national and global charities, nonprofits and foundations.

Around the web

Positron, a New York-based nuclear imaging company, will now provide Upbeat Cardiology Solutions with advanced PET/CT systems and services. 

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.