3D imaging, temperature map allow physicians to see ablation of brain tumors

Researchers from the University of Southern California (USC) Viterbi School of Engineering are making radiofrequency ablation safer and faster with real-time thermal imaging and an associated probe device, according to an April 9 USC news release

The research was published online March 3 in IEEE Transactions on Biomedical Engineering. 

“Although ablation is becoming increasingly popular, there is still no thermal imaging technology in regular clinical use to monitor these procedures in real time and ensure that the correct thermal dose is delivered the first time,” said co-author and research assistant professor John Stang, PhD, of the Ming Hsieh Department of Electrical Engineering, in a prepared statement.  

The non-invasive procedure involves microwave signals being continuously transmitted and received into the designated treatment area. The signals and information from prior imaging examinations are then produced into a 3D quantitative temperature map of the region being operated on.  

Stang and co-author Mahta Moghaddam, PhD, director of the Microwave Systems, Sensors and Imaging Lab at USC, hope that the new method and device will guide a more focused treatment and ultimately reduce follow-up imaging exams, time in the operating room, overtreatment, and procedural risks and costs.  

“Without real-time monitoring, there is the potential for both under-treatment and over-treatment,” Moghaddam said in a prepared statement. “If there is under-treatment, doctors must perform additional rounds of thermal ablation until all of the tumor is destroyed. Each repeat ablation carries increased risk of infection or other complications and takes up more time in the operating room.” 

""

A recent graduate from Dominican University (IL) with a bachelor’s in journalism, Melissa joined TriMed’s Chicago team in 2017 covering all aspects of health imaging. She’s a fan of singing and playing guitar, elephants, a good cup of tea, and her golden retriever Cooper.

Around the web

Positron, a New York-based nuclear imaging company, will now provide Upbeat Cardiology Solutions with advanced PET/CT systems and services. 

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.