Readily available radiotracer offers new option in prostate cancer imaging

Nuclear medicine departments now have a new radiopharmaceutical option for staging prostate cancer during imaging exams.

The novel radiotracer—18F-PSMA-1007—was proven to be just as accurate as the commonly used material—68Ga-PSMA—for characterizing intermediate- or high-risk forms of the disease. It’s another dependable tool clinicians can use to determine cancer severity and potentially bolster staging for patients across the globe, researchers wrote in the April issue of the Journal of Nuclear Medicine.

“In view of the near-equal performance of the two tracers, this preliminary study suggests the routine use of 18F-PSMA-1007 in lieu of 68Ga-PSMA-11 for staging prostate cancer patients; clinicians can use either radiotracer based on availability,” Jonathan Kuten, MD, a nuclear medicine specialist at Tel Aviv Sourasky Medical Center in Israel, wrote.

In order to reach their conclusions, Kuten and colleagues prospectively performed 18F-PSMA-1007 and 68Ga-PSMA-11 PET/CT within 15 days of each other in 16 individuals who were set to undergo surgery. Both tracers revealed tumor locations with nearly the exact same diagnostic accuracy. In four patients, however, the novel material detected a second positive focus, three of which were confirmed to be cancer while a fourth showed chronic prostatitis.

Additionally, 18F-PSMA-1007 met the gold standard for prostate cancer imaging—histopathologic findings taken from radical prostatectomy samples.

Einat Even-Sapir, MD, director of the Institute for Nuclear Medicine at the Tel Aviv center, also pointed out that the novel radiotracer has a longer half-life, better pharmacokinetics, central mass production and “potentially better spatial resolution” compared to 68Ga-PSMA-11.

The researchers did confirm that their findings are preliminary and encouraged further studies to test the radiopharmaceutical in larger cohorts.

""

Matt joined Chicago’s TriMed team in 2018 covering all areas of health imaging after two years reporting on the hospital field. He holds a bachelor’s in English from UIC, and enjoys a good cup of coffee and an interesting documentary.

Around the web

Positron, a New York-based nuclear imaging company, will now provide Upbeat Cardiology Solutions with advanced PET/CT systems and services. 

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.

CMS has more than doubled the CCTA payment rate from $175 to $357.13. The move, expected to have a significant impact on the utilization of cardiac CT, received immediate praise from imaging specialists.